TCO-number: 7.1256 Written-by: WONG Creation-date: 8-Mar-88 11:36:26 Edit-checked: No Document: No TCO-tested: No Maintenance-release: No Hardware-related: No Program: actsym Problem: ACTSYM.MAC on TOPS-20 is different then on TOPS-10. Diagnosis: Edits were made on the 10 and never got updated on the 20 and vic verser. Solution: Merge both ACTSYM.MAC into one. [End of TCO 7.1256] TCO-number: 7.1146 Written-by: MCCOLLUM Creation-date: 24-Nov-87 15:26:31 Edit-checked: No Document: Yes TCO-tested: No Maintenance-release: No Hardware-related: No Program: CHKPNT Problem: CHKPNT can't find SYSTEM-DATA.BIN. Diagnosis: CHKPNT looks for this file on PS:<SYSTEM>. If a Login Structure is in use, the file is not on PS:. Solution: Change CHKPNT to look for the file on ACCOUNT:, which is defined by the monitor at startup as BS:<SYSTEM>. Note that the monitor uses this logical name when writing to the file. [End of TCO 7.1146] TCO-number: 7.1171 Written-by: GSCOTT Creation-date: 5-Jan-88 14:52:30 Edit-checked: No Document: No TCO-tested: No Maintenance-release: No Hardware-related: No Program: CHKPNT Problem: CHKPNT column overflows after edit 131. Diagnosis: Edit 131 had a problem in the offsets used in the usage data templates. Solution: Use the correct offsets. [End of TCO 7.1171] TCO-number: 7.1154 Written-by: MCCOLLUM Creation-date: 1-Dec-87 17:43:12 Edit-checked: No Document: Yes TCO-tested: No Maintenance-release: No Hardware-related: No Program: DLUSER Problem: When loading directories onto a structure, DLUSER will never change the parameters for a directory that already exists unless it is a system directory. Diagnosis: That is the way DLUSER is coded. Solution: Implement a /FORCE switch for the load command. When this switch is typed, DLUSER will always change the parameters for any directory found in the input file, regardless of its directory number. [End of TCO 7.1154] TCO-number: 7.1028 Written-by: RASPUZZI Creation-date: 28-Jul-87 14:35:06 Edit-checked: No Document: No TCO-tested: No Maintenance-release: No Hardware-related: No Program: MONSYM Problem: Silly error coming out of TCP code. Diagnosis: Misspelling of "retansmission". Solution: Fix spelling error. [End of TCO 7.1028] TCO-number: 7.1123 Written-by: GSCOTT Creation-date: 10-Nov-87 16:49:58 Edit-checked: No Document: Yes TCO-tested: No Maintenance-release: No Hardware-related: No Program: MONSYM Problem: Brain damage evident in MONSYM. Diagnosis: The .DBTIM symbol is defined twice with different values. The .DBTVS symbol is not defined. Solution: Define .DBTVS properly. [End of TCO 7.1123] TCO-number: 7.1234 Written-by: RASPUZZI Creation-date: 19-Feb-88 08:47:20 Edit-checked: No Document: No TCO-tested: No Maintenance-release: No Hardware-related: No Program: MONSYM Related-QAR: 100 Problem: ARGX27 misspelled in MONSYM. Diagnosis: Extra non-functional "b". Solution: Remove said "b" [End of TCO 7.1234] TCO-number: 7.1248 Written-by: GSCOTT Creation-date: 1-Mar-88 15:26:12 Edit-checked: No Document: No TCO-tested: No Maintenance-release: No Hardware-related: No Program: MONSYM Problem: Wrong value of .QBDMX. Diagnosis: Somehow there a a .QBDMX==4 after .QBDMX==5. Solution: Remove extra bad definition of .QBDMX. [End of TCO 7.1248] TCO-number: 7.1263 Written-by: RASPUZZI Creation-date: 24-Mar-88 14:21:29 Edited-by: RASPUZZI Edit-date: 25-Mar-88 08:31:09 Edit-checked: No Document: Yes TCO-tested: No Maintenance-release: No Hardware-related: No Program: MONSYM Routines-affected: MONSYM Problem: JSYS manual talks about a TCP JFN function number 0. That's nice but there is no indication of any such beast. Diagnosis: Forgetfulness. Solution: Add .TCMWD (default mode) to MONSYM as function 0. Also change the documentation to reflect the correct actions for TCP JFN modes. [End of TCO 7.1263]