ACCULOGIC, INC.
SIDE-3/ PLUS
| 
 
  | |
| 
 Data bus:  | 
 16-bit, ISA  | 
| 
 Size:  | 
 Half-length, half-height card  | 
| 
 Hard drives supported:  | 
 Two IDE(AT) drives  | 
| 
 Floppy drives supported:  | 
 Two 360KB, 720KB, 1.2MB, 1.44MB or 2.88MB  | 
| 
 CONNECTIONS  | |
| 
 Function  | 
 Location  | 
| 
 4-pin connector-Drive Active LED  | 
 J1  | 
| 
 40-pin AT Interface (IDE) connector  | 
 J2  | 
| 
 34-pin control cable connector-floppy drive  | 
 J3  | 
| 
 BIOS ADDRESS  | |||
| 
 Address  | 
 Jumper JP12  | 
 Jumper JP13  | |
| » | 
 C800h  | 
 open  | 
 open  | 
| 
 CC00h  | 
 open  | 
 closed  | |
| 
 D800h  | 
 closed  | 
 open  | |
| 
 DC00h  | 
 closed  | 
 closed  | |
| 
 USER CONFIGURABLE SETTINGS  | |||
| 
 Function  | 
 Location  | 
 Setting  | |
| » | 
 Floppy drive port address is 3F0-3F7h  | 
 JP6  | 
 open  | 
| 
 Floppy drive port address is 370-377h  | 
 JP6  | 
 closed  | |
| » | 
 Hard drive port address is 1F0-1F7h  | 
 JP7  | 
 open  | 
| 
 Hard drive port address is 170-177h  | 
 JP7  | 
 closed  | |
| » | 
 Single speed floppy drives supported  | 
 JP8  | 
 open  | 
| 
 Dual speed floppy drives supported  | 
 JP8  | 
 closed  | |
| » | 
 Floppy drive precompensation is 125ns  | 
 JP9  | 
 open  | 
| 
 Floppy drive precompensation is 187ns  | 
 JP9  | 
 closed  | |
| » | 
 I/O Channel Ready signal disabled  | 
 JP10  | 
 open  | 
| 
 I/O Channel Ready signal enabled  | 
 JP10  | 
 closed  | |
| » | 
 BIOS enabled  | 
 JP11  | 
 open  | 
| 
 BIOS disabled  | 
 JP11  | 
 closed  | |
| » | 
 2.88MB drives not supported on A:  | 
 JP14  | 
 open  | 
| 
 2.88MB drives supported on A:  | 
 JP14  | 
 closed  | |
| » | 
 2.88MB drives not supported on B:  | 
 JP15  | 
 open  | 
| 
 2.88MB drives supported on B:  | 
 JP15  | 
 closed  | |
| 
 IRQ14 STATUS  | |||
| 
 Function  | 
 Jumper JP1  | 
 Jumper JP2  | |
| » | 
 IRQ14 normal  | 
 closed  | 
 open  | 
| 
 IRQ14 delayed until ACTIVE- signal is removed  | 
 open  | 
 closed  | |
| 
 MISCELLANEOUS TECHNICAL NOTES  | 
| 
 This Controller has no on-board software.  |