PROMISE TECHNOLOGY, INC.
OCTET CONDUCTOR
| 
 Card Type  | 
 Hard drive duplicator controller card  | 
| 
 Hard Drives supported  | 
 One master EIDE/IDE drive (eight target EIDE/IDE drives)  | 
| 
 Floppy drives supported  | 
 None  | 
| 
 Data Bus  | 
 32-bit VESA Local Bus  | 
| 
 Card Size  | 
 Full length, full-height card  | 
| 
 CONNECTIONS  | |||
| 
 Function  | 
 Location  | 
 Function  | 
 Location  | 
| 
 Primary connector to Octet Station via Cable1-IN  | 
 J1  | 
 Reserved connector - do not use  | 
 J4  | 
| 
 Secondary connector to Octet Station via Cable2-IN  | 
 J2  | 
 Reserved connector - do not use  | 
 J5  | 
| 
 Reserved connector - do not use  | 
 J3  | 
 Reserved connector - do not use  | 
 J6  | 
| 
 USER CONFIGURABLE SETTINGS  | |||
| 
 Function  | 
 Label  | 
 Position  | |
| » | 
 Factory configured - do not alter  | 
 J1  | 
 Pins 1 & 2 closed  | 
| » | 
 Factory configured - do not alter  | 
 J2  | 
 Pins 1 & 2 closed  | 
| » | 
 Factory configured - do not alter  | 
 J3  | 
 Pins 2 & 3 closed  | 
| » | 
 Factory configured - do not alter  | 
 J4  | 
 Pins 2 & 3 closed  | 
| » | 
 Factory configured - do not alter  | 
 J5  | 
 Pins 2 & 3 closed  | 
| 
 IRQ SELECTION (SECONDARY)  | |||||
| 
 IRQ  | 
 JP1  | 
 JP2  | 
 JP3  | 
 JP4  | |
| 
 10  | 
 Closed  | 
 Open  | 
 Open  | 
 Open  | |
| » | 
 11  | 
 Open  | 
 Closed  | 
 Open  | 
 Open  | 
| 
 14  | 
 Open  | 
 Open  | 
 Closed  | 
 Open  | |
| 
 15  | 
 Open  | 
 Open  | 
 Open  | 
 Closed  | |
| 
 Note: Users are advised not to change the default jumper settings.  | |||||
| 
 IRQ SELECTION (PRIMARY)  | |||||
| 
 IRQ  | 
 JP5  | 
 JP6  | 
 JP7  | 
 JP8  | |
| 
 10  | 
 Closed  | 
 Open  | 
 Open  | 
 Open  | |
| 
 11  | 
 Open  | 
 Closed  | 
 Open  | 
 Open  | |
| » | 
 14  | 
 Open  | 
 Open  | 
 Closed  | 
 Open  | 
| 
 15  | 
 Open  | 
 Open  | 
 Open  | 
 Closed  | |
| 
 Note: Users are advised not to change the default jumper settings.  | |||||
| 
 MISCELLANEOUS TECHNICAL INFORMATION  | 
| 
 The Octet Conductor controller provides the interface between host system and one Octet Station, where one master drive duplicates to eight target drives.  | 
OCTET STATION
| 
 CONNECTIONS  | |||
| 
 Function  | 
 Location  | 
 Function  | 
 Location  | 
| 
 Cable connector - master  | 
 CN0  | 
 Cable connector - CABLE1-IN  | 
 CN9  | 
| 
 Cable connector - target1  | 
 CN1  | 
 Cable connector - CABLE2-IN  | 
 CN10  | 
| 
 Cable connector - target2  | 
 CN2  | 
 Start/stop button  | 
 J2  | 
| 
 Cable connector - target3  | 
 CN3  | 
 Power connectors - master  | 
 J3  | 
| 
 Cable connector - target4  | 
 CN4  | 
 Power connectors - target  | 
 J4-J7  | 
| 
 Cable connector - target5  | 
 CN5  | 
 Power switch  | 
 J8  | 
| 
 Cable connector - target6  | 
 CN6  | 
 Power supply  | 
 J9  | 
| 
 Cable connector - target7  | 
 CN7  | 
 Voltage selector  | 
 J10  | 
| 
 Cable connector - target8  | 
 CN8  | ||
| 
 DIAGNOSTIC LED(S)  | |||
| 
 LED  | 
 Color  | 
 Status  | 
 Condition  | 
| 
 LED1  | 
 Green  | 
 On  | 
 Target drive 1 is active  | 
| 
 LED1  | 
 Green  | 
 Blinking  | 
 Duplication error on target 1or no hard drive 1  | 
| 
 LED1  | 
 Green  | 
 Off  | 
 Target drive 1 is idle  | 
| 
 LED2  | 
 Red  | 
 On  | 
 Power is on to target drives 1 & 2  | 
| 
 LED2  | 
 Red  | 
 Off  | 
 Power is off to target drives 1 & 2  | 
| 
 LED3  | 
 Green  | 
 On  | 
 Target drive 2 is active  | 
| 
 LED3  | 
 Green  | 
 Blinking  | 
 Duplication error on target 2 or no hard drive  | 
| 
 LED3  | 
 Green  | 
 Off  | 
 Target drive 2 is idle  | 
| 
 LED4  | 
 Green  | 
 On  | 
 Target drive 3 is active  | 
| 
 LED4  | 
 Green  | 
 Blinking  | 
 Duplication error on target 3 or no hard drive  | 
| 
 LED4  | 
 Green  | 
 Off  | 
 Target drive 3 is idle  | 
| 
 LED5  | 
 Red  | 
 On  | 
 Power is on to target drives 3 & 4  | 
| 
 LED5  | 
 Red  | 
 Off  | 
 Power is off to target drives 3 & 4  | 
| 
 LED6  | 
 Green  | 
 On  | 
 Target drive 4 is active  | 
| 
 LED6  | 
 Green  | 
 Blinking  | 
 Duplication error on target 4 or no hard drive  | 
| 
 LED6  | 
 Green  | 
 Off  | 
 Target drive 4 is idle  | 
| 
 LED7  | 
 Green  | 
 On  | 
 Target drive 5 is active  | 
| 
 LED7  | 
 Green  | 
 Blinking  | 
 Duplication error on target 5 or no hard drive  | 
| 
 LED7  | 
 Green  | 
 Off  | 
 Target drive 5 is idle  | 
| 
 LED8  | 
 Red  | 
 On  | 
 Power is on to target drives 5 & 6  | 
| 
 LED8  | 
 Red  | 
 Off  | 
 Power is off to target drives 5 & 6  | 
| 
 LED9  | 
 Green  | 
 On  | 
 Target drive 6 is active  | 
| 
 LED9  | 
 Green  | 
 Blinking  | 
 Duplication error on target 6 or no hard drive  | 
| 
 LED9  | 
 Green  | 
 Off  | 
 Target drive 6 is idle  | 
| 
 LED10  | 
 Green  | 
 On  | 
 Target drive 7 is active  | 
| 
 LED10  | 
 Green  | 
 Blinking  | 
 Duplication error on target 7 or no hard drive  | 
| 
 LED10  | 
 Green  | 
 Off  | 
 Target drive 7 is idle  | 
| 
 LED11  | 
 Red  | 
 On  | 
 Power is on to target drives 7 & 8  | 
| 
 LED11  | 
 Red  | 
 Off  | 
 Power is off to target drives 7 & 8  | 
| 
 LED12  | 
 Green  | 
 On  | 
 Target drive 8 is active  | 
| 
 LED14  | 
 Green  | 
 Blinking  | 
 Duplication error on target 8 or no hard drive  | 
| 
 LED12  | 
 Green  | 
 Off  | 
 Target drive 8 is idle  | 
| 
 LED13  | 
 Red  | 
 On  | 
 Power is on to master drive  | 
| 
 LED13  | 
 Red  | 
 Off  | 
 Power is off to master drive  | 
| 
 LED14  | 
 Green  | 
 On  | 
 Master drive is active  | 
| 
 LED14  | 
 Green  | 
 Off  | 
 Master drive is idle  | 
| 
 LED15  | 
 Red  | 
 On  | 
 Octet Station is on  | 
| 
 LED15  | 
 Red  | 
 On  | 
 Octet Station is off  |