STORAGE DIMENSIONS
DGR ULTRA RAIDCARD
| 
 Card Type  | 
 Hard drive controller  | 
| 
 Processor  | 
 Intel i960CA 32-bit RISC  | 
| 
 Chipset:  | 
 Intel Neptune/Mercury  | 
| 
 Maximum On Board Memory  | 
 128MB  | 
| 
 Hard Drives Supported  | 
 Up to 21 Wide SCSI devices  | 
| 
 Floppy Drives Supported  | 
 None  | 
| 
 Data Bus  | 
 32-bit PCI  | 
| 
 Card Size  | 
 Full length, full height  | 
| 
 Raid Levels Supported  | 
 0,1,3,5, 1/0, 3/0, 5/0  | 
| 
 CONNECTIONS  | |||
| 
 Function  | 
 Location  | 
 Function  | 
 Location  | 
| 
 68-pin SCSI Wide connector channel 1 - internal  | 
 J4  | 
 Dirty cache LED connector  | 
 J12  | 
| 
 68-pin SCSI Wide connector channel 2 - internal  | 
 J5  | 
 Cache battery backup connector  | 
 J19  | 
| 
 68-pin SCSI Wide connector channel 3 - internal  | 
 J6  | 
 68-pin SCSI Wide connector channel 2 - external  | 
 J26  | 
| 
 4-pin connector - drive active LED  | 
 J10  | 
 68-pin SCSI Wide connector channel 1 - external  | 
 J27  | 
| 
 USER CONFIGURABLE SETTINGS  | |||
| 
 Function  | 
 Label  | 
 Position  | |
| » | 
 Expansion BIOS enabled  | 
 J2  | 
 Closed  | 
| 
 Expansion BIOS disabled  | 
 J2  | 
 Open  | |
| » | 
 Intel Triton chipset not on motherboard  | 
 J28  | 
 Pins 1 & 2 closed  | 
| 
 Intel Triton chipset on motherboard  | 
 J28  | 
 Pins 2 & 3 closed  | |
| 
 Note:If there is more than one DGR RAIDCard in the system, disable expansion BIOS on all but one card.  | |||
| 
 TERMINATION POWER SELECTION FOR CHANNEL 1  | ||
| 
 Setting  | 
 J20  | |
| » | 
 TERMPWR supplied by PCI bus of host system  | 
 Pins 1 & 2 closed  | 
| 
 TERMPWR supplied by auxiliary power source  | 
 Pins 2 & 3 closed  | |
| 
 TERMPWR supplied by SCSI interface  | 
 Open  | |
| 
 TERMINATION POWER SELECTION FOR CHANNEL 2  | ||
| 
 Setting  | 
 J17  | |
| » | 
 TERMPWR supplied by PCI bus of host system  | 
 Pins 1 & 2 closed  | 
| 
 TERMPWR supplied by auxiliary power source  | 
 Pins 2 & 3 closed  | |
| 
 TERMPWR supplied by SCSI interface  | 
 Open  | |
| 
 TERMINATION POWER SELECTION FOR CHANNEL 3  | ||
| 
 Setting  | 
 J7  | |
| » | 
 TERMPWR supplied by PCI bus of host system  | 
 Pins 1 & 2 closed  | 
| 
 TERMPWR supplied by auxiliary power source  | 
 Pins 2 & 3 closed  | |
| 
 TERMPWR supplied by SCSI interface  | 
 Open  | |
| 
 DRAM CONFIGURATION  | ||
| 
 Size  | 
 Bank 0  | 
 Bank 1  | 
| 
 4MB  | 
 (1) 1M x 36  | 
 None  | 
| 
 16MB  | 
 (1) 4M x 36  | 
 None  | 
| 
 32MB  | 
 (1) 4M x 36  | 
 (1) 4M x 36  | 
| 
 64MB  | 
 (1) 16M x 36  | 
 None  | 
| 
 128MB  | 
 (1) 16M x 36  | 
 (1) 16M x 36  | 
| 
 Note:If SIMMs of different size are used, the total memory will be twice the size of the smaller SIMM.  | ||