XEBEC AMERICA
S1410
| 
 Data Bus  | 
 External  | 
| 
 Card Size  | 
 5.25 in. form factor  | 
| 
 Hard Drives supported  | 
 Two ST-506/412(MFM) drives  | 
| 
 Floppy drives supported  | 
 None  | 
| 
 CONNECTIONS  | |||
| 
 Function  | 
 Location  | 
 Function  | 
 Location  | 
| 
 34-pin cable connector - hard drive  | 
 J1  | 
 Factory test connector - do not alter  | 
 J4  | 
| 
 20-pin data cable connector - drive 1  | 
 J2  | 
 4-pin power connector  | 
 P1  | 
| 
 20-pin data cable connector - drive 2  | 
 J3  | 
 50-pin SASI connector - external  | 
 P2  | 
| 
 Note: P2 is the interface to the host adapter. See Miscellaneous Technical Note.  | |||
| 
 USER CONFIGURABLE SETTINGS  | |||
| 
 Function  | 
 Label  | 
 Position  | |
| » | 
 Factory configured - do not alter  | 
 W1  | 
 Closed  | 
| » | 
 Factory configured - do not alter  | 
 W2  | 
 Closed  | 
| » | 
 Sector size is 256 bytes, 32 sectors/track  | 
 W3  | 
 Pins 1 & 2 closed  | 
| 
 Sector size is 512 bytes, 17 sectors/track  | 
 W3  | 
 Pins 2 & 3 closed  | |
| 
 SASI ID SELECTION  | ||
| 
 Setting  | 
 Connection  | |
| » | 
 0  | 
 Pin O0 to pin S closed  | 
| 
 1  | 
 Pin O1 to pin S closed  | |
| 
 2  | 
 Pin O2 to pin S closed  | |
| 
 3  | 
 Pin O3 to pin S closed  | |
| 
 4  | 
 Pin O4 to pin S closed  | |
| 
 5  | 
 Pin O5 to pin S closed  | |
| 
 6  | 
 Pin O6 to pin S closed  | |
| 
 7  | 
 Pin O7 to pin S closed  | |
| 
 MISCELLANEOUS TECHNICAL NOTE  | 
| 
 Note: The S1410 controller card is connected to the host adapter via the SASI bus (connector P2). Multiple controller cards may be daisy chained on this cable, with each controller assigned a unique SASI ID. When mutiple controllers are chained, install the terminator on the last card on the chain.  |