CABLETRON SYSTEMS, INC.
E6010/-X (Twisted pair)
| 
 NIC Type  | 
 Ethernet  | 
| 
 Transfer Rate  | 
 10Mbps  | 
| 
 Data Bus  | 
 32-bit NuBus (Apple)  | 
| 
 Topology  | 
 Star  | 
| 
 Wiring Type  | 
 Unshielded twisted pair AUI transceiver via DB-15 port  | 
| 
 Boot ROM  | 
 Not Available  | 
| 
 SIGNAL QUALITY ERROR (SQE) TEST  | ||
| 
 Setting  | 
 JP2  | |
| » | 
 Disabled  | 
 Pins 2 & 3 Closed  | 
| 
 Enabled  | 
 Pins 1 & 2 Closed  | |
| 
 Note:Signal Quality Error (SQE) is a test of the collision circuitry and path.  | ||
| 
 CABLE TYPE  | ||
| 
 Type  | 
 Switch PSS  | |
| » | 
 Unshielded twisted pair  | 
 On  | 
| 
 AUI transceiver via DB-15 port  | 
 Off  | |
| 
 DIAGNOSTIC LED(S)  | |||
| 
 LED  | 
 Color  | 
 Status  | 
 Condition  | 
| 
 1  | 
 Green  | 
 On/Blinking  | 
 Data is being transmitted  | 
| 
 1  | 
 Green  | 
 Off  | 
 Data is not being transmitted  | 
| 
 2  | 
 Red  | 
 On/Blinking  | 
 Collision detected on network  | 
| 
 2  | 
 Red  | 
 Off  | 
 Normal operation  | 
| 
 3  | 
 Yellow  | 
 On/Blinking  | 
 Data is being received  | 
| 
 3  | 
 Yellow  | 
 Off  | 
 Data is not being received  | 
| 
 4  | 
 Green  | 
 On  | 
 Twisted pair network connection is good  | 
| 
 4  | 
 Green  | 
 Off  | 
 Twisted pair network connection is broken  |