PURE DATA, LTD.
PDI7023-16CAT
| 
 NIC Type  | 
 Ethernet  | 
| 
 Transfer Rate  | 
 10Mbps  | 
| 
 Data Bus  | 
 16-bit ISA  | 
| 
 Topology  | 
 Star Linear bus  | 
| 
 Wiring Type  | 
 Unshielded twisted pair RG58A/U 50ohm coaxial AUI transceiver via DB-15 port  | 
| 
 Boot ROM  | 
 Not available  | 
| 
 COAXIAL SEGMENT LENGTH  | ||
| 
 Maximum Length  | 
 E1  | |
| » | 
 200 meters  | 
 Closed  | 
| 
 300 meters  | 
 Open  | |
| 
 INTERRUPT REQUEST  | |||||||||||
| 
 IRQ  | 
 E2A  | 
 E2B  | 
 E2C  | 
 E2D  | 
 E2E  | 
 E2F  | 
 E2G  | 
 E2H  | 
 E2I  | 
 E2J  | |
| 
 2/9  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Closed  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | |
| 
 3  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Closed  | |
| » | 
 4  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Closed  | 
 Open  | 
| 
 5  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Closed  | 
 Open  | 
 Open  | |
| 
 6  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Closed  | 
 Open  | 
 Open  | 
 Open  | |
| 
 7  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Closed  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | |
| 
 10  | 
 Open  | 
 Open  | 
 Open  | 
 Closed  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | |
| 
 11  | 
 Open  | 
 Open  | 
 Closed  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | |
| 
 12  | 
 Open  | 
 Closed  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | |
| 
 15  | 
 Closed  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | |
| 
 CABLE TYPE  | ||
| 
 Type  | 
 Isolation Transformer Location  | |
| » | 
 Unshielded twisted pair  | 
 N/A  | 
| 
 RG58A/U 50ohm coaxial  | 
 T2  | |
| 
 AUI transceiver via DB-15 port  | 
 T3  | |
| 
 Note:The cable type is automatically selected, but the isolation transformer must be moved to the proper socket to enable the BNC connector or DB-15 port.
  | ||
| 
 I/O BASE ADDRESS  | ||||
| 
 Address  | 
 SW1/1  | 
 SW1/2  | 
 SW1/3  | |
| 
 260h  | 
 On  | 
 On  | 
 On  | |
| 
 290h  | 
 Off  | 
 On  | 
 On  | |
| 
 2E0h  | 
 On  | 
 Off  | 
 On  | |
| 
 2F0h  | 
 Off  | 
 Off  | 
 On  | |
| » | 
 300h  | 
 On  | 
 On  | 
 Off  | 
| 
 350h  | 
 Off  | 
 On  | 
 Off  | |
| 
 380h  | 
 On  | 
 Off  | 
 Off  | |
| 
 3E0h  | 
 Off  | 
 Off  | 
 Off  | |
| 
 EXTENDED TRANSMIT TIMEOUT  | ||
| 
 Setting  | 
 SW1/5  | |
| » | 
 Enabled  | 
 On  | 
| 
 Disabled  | 
 Off  | |
| 
 Note:With this option enabled, if the card is transmitting for an extended amount of time the transmission will be interrupted and continued after a preset time. This keeps one card from dominating the network.  | ||
| 
 LINK INTEGRITY TEST  | ||
| 
 Setting  | 
 SW1/7  | |
| » | 
 Enabled  | 
 On  | 
| 
 Disabled  | 
 Off  | |
| 
 Note:The link integrity test is valid only when the cable type is unshielded twisted pair.  | ||
| 
 FACTORY CONFIGURED SETTINGS  | |
| 
 Switch  | 
 Setting  | 
| 
 SW1/4  | 
 Off  | 
| 
 SW1/6  | 
 On  | 
| 
 SW1/8  | 
 Off  | 
| 
 DIAGNOSTIC LED(S)  | |||
| 
 LED  | 
 Color  | 
 Status  | 
 Condition  | 
| 
 LED1  | 
 Green  | 
 On  | 
 Data is being transmitted or received  | 
| 
 LED1  | 
 Green  | 
 Off  | 
 Data is not being transmitted or received  | 
| 
 LED2  | 
 Red  | 
 On  | 
 Card is being accessed by host computer  | 
| 
 LED2  | 
 Red  | 
 Off  | 
 Card is not being accessed by host computer  | 
| 
 LED3  | 
 Red  | 
 On  | 
 Collision detected on network  | 
| 
 LED3  | 
 Red  | 
 Off  | 
 Normal operation  | 
| 
 LED4  | 
 Green  | 
 On  | 
 Cable type is AUI via DB-15 or RG-58A/U coaxial  | 
| 
 LED4  | 
 Green  | 
 Off  | 
 Cable type is Twisted pair  |