THOMAS-CONRAD CORPORATION
TC6242-TP+
| 
 NIC Type  | 
 ARCnet  | 
| 
 Transfer Rate  | 
 2.5Mbps  | 
| 
 Data Bus  | 
 8-bit ISA  | 
| 
 Topology  | 
 Star Linear Bus  | 
| 
 Wiring Type  | 
 Twisted Pair Plus  | 
| 
 Boot ROM  | 
 Available  | 
| 
 NODE ADDRESS  | ||||||||
| 
 Node  | 
 SW2/ 1  | 
 SW2/ 2  | 
 SW2/ 3  | 
 SW2/ 4  | 
 SW2/ 5  | 
 SW2/ 6  | 
 SW2/ 7  | 
 SW2/ 8  | 
| 
 0  | 
 -  | 
 -  | 
 -  | 
 -  | 
 -  | 
 -  | 
 -  | 
 -  | 
| 
 1  | 
 Off  | 
 On  | 
 On  | 
 On  | 
 On  | 
 On  | 
 On  | 
 On  | 
| 
 2  | 
 On  | 
 Off  | 
 On  | 
 On  | 
 On  | 
 On  | 
 On  | 
 On  | 
| 
 3  | 
 Off  | 
 Off  | 
 On  | 
 On  | 
 On  | 
 On  | 
 On  | 
 On  | 
| 
 4  | 
 On  | 
 On  | 
 Off  | 
 On  | 
 On  | 
 On  | 
 On  | 
 On  | 
| 
 251  | 
 Off  | 
 Off  | 
 On  | 
 Off  | 
 Off  | 
 Off  | 
 Off  | 
 Off  | 
| 
 252  | 
 On  | 
 On  | 
 Off  | 
 Off  | 
 Off  | 
 Off  | 
 Off  | 
 Off  | 
| 
 253  | 
 Off  | 
 On  | 
 Off  | 
 Off  | 
 Off  | 
 Off  | 
 Off  | 
 Off  | 
| 
 254  | 
 On  | 
 Off  | 
 Off  | 
 Off  | 
 Off  | 
 Off  | 
 Off  | 
 Off  | 
| 
 255  | 
 Off  | 
 Off  | 
 Off  | 
 Off  | 
 Off  | 
 Off  | 
 Off  | 
 Off  | 
| 
 Note: Node address 0 is used for messaging between nodes and must not be used. A total of 255 node address settings are available. The switches are a binary representation of the decimal node addresses. Switch 1 is the Least Significant Bit and switch 8 is the Most Significant Bit. The switches have the following decimal values: switch 1=1, 2=2, 3=4, 4=8, 5=16, 6=32, 7=64, 8=128. Turn off the switches and add the values of the off switches to obtain the correct node address. (On=0, off=1)  | ||||||||
| 
 INTERRUPT REQUEST  | ||||||
| 
 IRQ  | 
 JP1  | 
 JP2  | 
 JP3  | 
 JP4  | 
 JP5  | |
| » | 
 2  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | 
 Closed  | 
| 
 3  | 
 Closed  | 
 Open  | 
 Open  | 
 Open  | 
 Open  | |
| 
 4  | 
 Open  | 
 Closed  | 
 Open  | 
 Open  | 
 Open  | |
| 
 5  | 
 Open  | 
 Open  | 
 Closed  | 
 Open  | 
 Open  | |
| 
 7  | 
 Open  | 
 Open  | 
 Open  | 
 Closed  | 
 Open  | |
| 
 RESPONSE AND RECONFIGURATION TIMEOUTS  | |||
| 
 Setting  | 
 JP6  | 
 JP7  | |
| » | 
 Network cable distance under 20,000 feet  | 
 Open  | 
 Open  | 
| 
 Network cable distance greater than 20,000 feet  | 
 Closed  | 
 Closed  | |
| 
 Note:All NICs on the network must have these two jumpers set the same.  | |||
| 
 BASE MEMORY ADDRESS  | |||||||
| 
 Address  | 
 SW1/1  | 
 SW1/2  | 
 SW1/3  | 
 SW1/4  | 
 SW1/5  | 
 SW1/6  | |
| » | 
 D000h  | 
 Off  | 
 Off  | 
 On  | 
 Off  | 
 On  | 
 On  | 
| 
 C000h  | 
 Off  | 
 Off  | 
 On  | 
 On  | 
 On  | 
 On  | |
| 
 C400h  | 
 Off  | 
 Off  | 
 On  | 
 On  | 
 On  | 
 Off  | |
| 
 C800h  | 
 Off  | 
 Off  | 
 On  | 
 On  | 
 Off  | 
 On  | |
| 
 CC00h  | 
 Off  | 
 Off  | 
 On  | 
 On  | 
 Off  | 
 Off  | |
| 
 D400h  | 
 Off  | 
 Off  | 
 On  | 
 Off  | 
 On  | 
 Off  | |
| 
 D800h  | 
 Off  | 
 Off  | 
 On  | 
 Off  | 
 Off  | 
 On  | |
| 
 DC00h  | 
 Off  | 
 Off  | 
 On  | 
 Off  | 
 Off  | 
 Off  | |
| 
 COMPATIBILITY MODE  | ||
| 
 Setting  | 
 SW1/ 8  | |
| » | 
 Enhanced mode  | 
 On  | 
| 
 Compatible mode  | 
 Off  | |
| 
 Note: Enhanced mode optimizes performance and minimizes conflicts of your hardware by using a Thomas-Conrad
  | ||
| 
 I/O BASE ADDRESS  | |||||||
| 
 Address  | 
 SW3/3  | 
 SW3/4  | 
 SW3/5  | 
 SW3/6  | 
 SW3/7  | 
 SW3/8  | |
| » | 
 2E0h  | 
 Off  | 
 On  | 
 Off  | 
 Off  | 
 Off  | 
 On  | 
| 
 2F0h  | 
 Off  | 
 On  | 
 Off  | 
 Off  | 
 Off  | 
 Off  | |
| 
 300h  | 
 Off  | 
 Off  | 
 On  | 
 On  | 
 On  | 
 On  | |
| 
 310h  | 
 Off  | 
 Off  | 
 On  | 
 On  | 
 On  | 
 Off  | |
| 
 320h  | 
 Off  | 
 Off  | 
 On  | 
 On  | 
 Off  | 
 On  | |
| 
 330h  | 
 Off  | 
 Off  | 
 On  | 
 On  | 
 Off  | 
 Off  | |
| 
 340h  | 
 Off  | 
 Off  | 
 On  | 
 Off  | 
 On  | 
 On  | |
| 
 350h  | 
 Off  | 
 Off  | 
 On  | 
 Off  | 
 On  | 
 Off  | |
| 
 360h  | 
 Off  | 
 Off  | 
 On  | 
 Off  | 
 Off  | 
 On  | |
| 
 370h  | 
 Off  | 
 Off  | 
 On  | 
 Off  | 
 Off  | 
 Off  | |
| 
 380h  | 
 Off  | 
 Off  | 
 Off  | 
 On  | 
 On  | 
 On  | |
| 
 390h  | 
 Off  | 
 Off  | 
 Off  | 
 On  | 
 On  | 
 Off  | |
| 
 3A0h  | 
 Off  | 
 Off  | 
 Off  | 
 On  | 
 Off  | 
 On  | |
| 
 3B0h  | 
 Off  | 
 Off  | 
 Off  | 
 On  | 
 Off  | 
 Off  | |
| 
 3C0h  | 
 Off  | 
 Off  | 
 Off  | 
 Off  | 
 On  | 
 On  | |
| 
 3D0h  | 
 Off  | 
 Off  | 
 Off  | 
 Off  | 
 On  | 
 Off  | |
| 
 3E0h  | 
 Off  | 
 Off  | 
 Off  | 
 Off  | 
 Off  | 
 On  | |
| 
 3F0h  | 
 Off  | 
 Off  | 
 Off  | 
 Off  | 
 Off  | 
 Off  | |
| 
 FACTORY CONFIGURED SETTINGS - DO NOT ALTER  | |
| 
 Switch  | 
 Setting  | 
| 
 SW3/1  | 
 On  | 
| 
 SW3/2  | 
 On  | 
| 
 DIAGNOSTIC LED(S)  | ||
| 
 LED  | 
 Status  | 
 Condition  | 
| 
 LED1  | 
 On  | 
 Data is being transmitted/received.  | 
| 
 LED1  | 
 Off  | 
 Data is not being transmitted/received.  |