TECMAR
WANGTEK 5150ES (33678-XXX VER.2)
| 
 Device Type  | 
 Internal Tape Drive  | 
| 
 Interface  | 
 SCSI  | 
| 
 Format  | 
 QIC-120, QIC-150 (write) QIC-24, QIC-120, QIC-150 (read)  | 
| 
 Sustained Transfer Rate  | 
 1800KBPS  | 
| 
 Size  | 
 5.25 in. half height  | 
| 
 View  | 
 Bottom  | 

| 
 CONNECTIONS  | 
|
| 
 Function  | 
 Label  | 
| 
 Ground connector  | 
 CN1  | 
| 
 USER CONFIGURABLE SETTINGS  | 
|||
| 
 Setting  | 
 Label  | 
 Position  | 
|
| 
 »  | 
 Ground connector enabled  | 
 E2  | 
 Closed  | 
| 
 
  | 
 Ground connector disabled  | 
 E2  | 
 Open  | 
| 
 »  | 
 Factory configured - do not alter  | 
 E5  | 
 Closed  | 
| 
 »  | 
 Factory configured - do not alter  | 
 E20/0  | 
 Open  | 
| 
 »  | 
 Factory configured - do not alter  | 
 E20/1  | 
 Open  | 
| 
 »  | 
 Factory configured - do not alter  | 
 E20/2  | 
 Open  | 
| 
 »  | 
 Factory configured - do not alter (Diagnostic test connector)  | 
 J32  | 
 Open  | 
| 
 DRIVE SELECT ID  | 
|||
| 
 Drive ID  | 
 J10/A  | 
 J10/B  | 
 J10/C  | 
| 
 0  | 
 Open  | 
 Open  | 
 Open  | 
| 
 1  | 
 Closed  | 
 Open  | 
 Open  | 
| 
 2  | 
 Open  | 
 Closed  | 
 Open  | 
| 
 3  | 
 Closed  | 
 Closed  | 
 Open  | 
| 
 4  | 
 Open  | 
 Open  | 
 Closed  | 
| 
 5  | 
 Closed  | 
 Open  | 
 Closed  | 
| 
 6  | 
 Open  | 
 Closed  | 
 Closed  | 
| 
 7  | 
 Closed  | 
 Closed  | 
 Closed  | 
| 
 Note: The function of jumper J10/D is unidentified. It is factory configured and should not be altered.  | 
|||
| 
 TERMINATION POWER SELECTION  | 
||
| 
 Setting  | 
 E1  | 
|
| 
 »  | 
 TERMPWR supplied by drive  | 
 Closed  | 
| 
 
  | 
 TERMPWR supplied by SCSI interface to drive  | 
 Open  | 
| 
 MANUFACTURERS RECOMMENDED MEDIA  | 
|
| 
 Tape  | 
 Capacity  | 
| 
 DC 600A  | 
 125 MB (in QIC-120 mode)  | 
| 
 DC 6150  | 
 150 MB (in QIC-150 mode)  | 
| 
 DC 6250  | 
 250 MB (in QIC-150 mode)  | 
| 
 DIAGNOSTIC LED(S)  | 
| 
 Note: Function and location of LED(s) is/are unidentified.  | 
| 
 MISCELLANEOUS TECHNICAL NOTES  | 
| 
 Termination is enabled or disabled via the three terminating resistors (see diagram).  |