| Processor |
| Number |
4 to 64 |
| Architecture |
250, 336, 400, or 466 MHz UltraSPARC[tm]-II |
| Cache per processor |
Primary: 16-KB instruction, and 16-KB data on chip
Secondary: 4-MB external cache or 8-MB external cache (466
MHz module) |
| CPU interface |
64-bit Ultra Port Architecture (UPA) |
| System Interconnect |
Gigaplane-XB interconnect, 12.8 GB/second throughput
Memory data bus: 576 bits
Data bus: 144 bits per board
CPU data bus: 144 bits
|
| System
Boards |
| Number of boards |
Maximum of 16 boards per Enterprise 10000 server; minimum
configuration is one system board |
| CPU/Memory board |
Up to four processors and four banks of eight memory SIMMs on each system
board |
| I/O Board |
Up to four SBus cards or two PCI cards on each system board |
| Control Board |
Up to two boards per Enterprise 10000 server; controls the system JTAG,
clock, fan, power, serial interface, and Ethernet interface functions |
| Main
Memory |
|
2-GB to 64-GB memory capacity per system
256-MB and 1-GB memory expansion options (each a group
of 8 SIMMs)
Up to four memory expansion options per system board
|
| Standard
Interfaces |
| Ethernet |
One twisted-pair ethernet (10BASE-T) port (RJ-45)
per Control Board; for use only between the Control Board(s) and the System
Service Processor(s) |
| PCI |
Two slots per PCI I/O module mounted on the System Board;
32-bit or 64-bit data bus width, 33- or 66-MHz, short cards (6.5-inch) |
| SBus |
Four slots per SBus I/O module mounted on the System Board; 32-bit or
64-bit data bus width, 25 MHz |
| Internal
Mass Storage |
| Disk Array/Tray |
Maximum of two Sun StorEdge D1000 arrays (capacity up
to 2 TB)
or
Maximum of 16 UniPack disks and 4 UniPack trays
or
a combination of both
|
| Power
Supplies |
|
N+1 system redundancy
Universal 220 VAC-to-48 DC volt
up to 2 AC power sequencers
|
| Environment |
| AC input1 |
200 - 240 VAC, 47 - 63 Hz, 24 A (max) |
| Input power |
13,456 W |
| Heat output |
52,000 BTU/hr |
| Temperature |
Optimal: 21° C to 23° C (70° F to 74° F)
Operating: 10° C to 32° C (50° F to 90° F)
Nonoperating: -40° C to 65° C (-40° F to 149° F)
|
| Humidity2 |
Optimal: 45% to 50% relative humidity, noncondensing
Operating: 20% to 80% relative humidity, noncondensing
Nonoperating: Up to 93% relative humidity, noncondensing |
| Altitude |
Operating: 3000 m (10,000 ft.)
Nonoperating: 12,000 m (40,000 ft.) |
| Number of cords |
5 (max) |
| Plug type - U.S. |
NEMA L6-30P, 200 - 240 VAC |
| Plug type - International |
IEC 309, 32 A, 220 - 240 VAC |
1 Per line cord;
up to five redundant line cords
2 Operating temperature ramp rate
not to exceed 68° F (20° C) per hour, humidity ramp rate not to
exceed 30% relative humidity per hour. Nonoperating temperature ramp rate
not to exceed 59° F (15° C) per hour, humidity ramp rate not to
exceed 20% relative humidity per hour. |
Regulations
Meets or exceeds the following requirements: |
| Safety |
UL 1950, CUL CAN/CSA 22:2 M950, TUV EN60950 |
| RFI/EMI |
FCC Class A, EN50021-1 Class A |
| Immunity |
EN50082-1 |
| Dimensions
and Weights |
| Height |
177.8 cm (70 in.)
200 cm (78.75 in.) shipping |
| Width |
97.2 cm (38.25 in.)
123.8 cm (48.75 in.) shipping |
| Depth |
126.8 cm (49.9 in.)
155.6 cm (61.25 in.) shipping |
| Weight |
909 kg (2000 lb.) approximate
1000 kg (2200 lb.) approximate shipping |
| Power Cord |
4.6 m (15 ft.) |
| Clearance
and Service Access |
| Front1 |
40.6 cm (16 in.) |
| Rear1 |
40.6 cm (16 in.) |
| 1 If no peripheral is over 50.8
cm (20 in.); if a peripheral is over 50.8 cm (20 in.), add additional access
space to accommodate the excess length. |