N D - 4 3 8 0 E NEWBURY DATA NO MORE PRODUCED Native| Translation ------+-----+-----+----- Form 5.25"/FH Cylinders 1224| | | Capacity form/unform 338/ 384 MB Heads 15| | | Seek time / track 17.0/ 3.0 ms Sector/track 36| | | Controller ESDI Precompensation 65535 Cache/Buffer KB Landing Zone Data transfer rate 1.250 MB/S int Bytes/Sector 512 MB/S ext Recording method RLL operating | non-operating -------------+-------------- Supply voltage 5/12 V Temperature *C 10 55 | -40 60 Power: sleep W Humidity % 8 80 | 8 80 standby W Altitude km 3.048| -0.305 12.192 idle W Shock g 2 | 25 seek 27.0 W Rotation RPM 3600 read/write W Acoustic dBA spin-up W ECC Bit MTBF h 150000 Warranty Month Lift/Lock/Park YES Certificates CSA,FCC,IEC380,IEC950,UL47... ********************************************************************** L A Y O U T ********************************************************************** MAXTOR XT-4000E FAMILY QUICK REFERENCE GUIDE 1018329 REV. B +----------------+--------+-------------------------------+ | +--J4----+ JP42++JP1 |XX | +-JP41 ++++ |XX J2 | +-+ |XX | |XX | DS1-DS7 | | E15+++++++++|XX | JP24 - 16 ++++++++++|XX | ++++++++++ +-RN13---+|XX | ++++++++++ +--------+|XX J1 | JP25-31+++++++ +--JP45 +-RN14---+|XX | ++++++++ +--+ +--------+|XX +-J5 +++++++++ +-+ | | +++++++++ JP14+ J6+| | | JP39 - 32 ++ +-+| +-+ ++ +-+ | +JP6 |XX J3 | |XX Power +---------------------------------------------------------+ ********************************************************************** J U M P E R S ********************************************************************** MAXTOR XT-4000E FAMILY QUICK REFERENCE GUIDE 1018329 REV. B Jumper Setting ============== x = Jumper set at factory Jumper Selections ----------------- +------------+--------------------------------------------+ |JP1 (IN) |Used for Manufacturing Testing | +------------+--------------------------------------------+ |JP6 (IN) |IN = Motor Spinup Option Disabled | | |OUT = Remote Motor Spinup Option Enabled | +------------+--------------------------------------------+ |DS1-DS7 |Drive Select | +------------+--------------------------------------------+ |JP14 (OUT) |IN = Write Protected | | |OUT = No Write Protection | +------------+--------------------------------------------+ |JP16-JP29 |Unformatted Hard Sector Size in Bytes | | |Jumpers, LSB = JP16, MSB = JP29 | +------------+--------------------------------------------+ |JP30 |IN = Enables Programming of the Hard Sector | | |Size through the interface | | |OUT = Disable this Function | +------------+--------------------------------------------+ |JP31 |IN = Soft Sector Mode | | |OUT = Hard Sector Mode | +------------+--------------------------------------------+ |JP32-35,JP38|PCB Head Configuration | +------------+--------------------------------------------+ |JP41 |Test Connection, not a jumperable Option | +------------+--------------------------------------------+ |JP42 (IN) |Used for Manufacturing Testing | +------------+--------------------------------------------+ |JP45 |Used for Conversion to Short Index | | |1, 2 = Standard Index (70 S), 2, 3 Short | | |Index (3 S) | +------------+--------------------------------------------+ |Note: JP4, JP5, JP15, JP36, JP39, JP40, JP41 are NOT | |Jumperable Options. The only Customer Configurable | |Options are JP6, JP14, JP16-JP29, JP30, JP31, JP45, and | |DS1-DS7. | +---------------------------------------------------------+ Drive Address Selection ----------------------- +------------+-----------+ |Drive Select| Jumper | |Number | Installed | +------------+-----------+ | x 1 | DS1 | +------------+-----------+ | 2 | DS2 | +------------+-----------+ | 3 | DS3 | +------------+-----------+ | 4 | DS4 | +------------+-----------+ | 5 | DS5 | +------------+-----------+ | 6 | DS6 | +------------+-----------+ | 7 | DS7 | +------------+-----------+ In multidrive configurations, it is necessary to configure each drive with a unique address. A maximum of seven drives are permitted per single host controller. The address for the drive is determined by installing the jumper plug in the appropriate jumper location. As shipped from the factory, the drive is configured as logical unit number one. Removing the jumper entirely is equivalent to a "no select". JP6 Option for Sequential Spindle Motor Spinup Jumper ------------------------------------------------------ x JP6 CLOSED The drive automatically spins up as soon as power is applied. OPEN The drive is started be issuing the appropriate command from the controller. The spindle motor spinup jumper allows a string of drives to be started sequentially by the controller. JP14 Write Protect Selection Jumper ------------------------------------ JP14 CLOSED The drive is write protected and can only be read; no writing may take place. x OPEN The drive is not write protected. JP16-JP31 Hard Sector Configuration Jumpers -------------------------------------------- Jumper JP31 selects the mode of operation. Jumper JP31 installed configures the drive as a soft sectored drive; removed, it configures the drive as a hard sectored drive. Jumpers JP16 through JP29 allow the user to configure the drive's hard sector size. The sector size can range from a minimum of 123 to a maximum of 10,470 unformatted bytes per sector, with 1 byte granularity. The hard sector configuration jumpers are encoded in a binary fashion, with JP16 being the least significant byte and JP29 being the most significant byte. An installed jumper equates to a one. Jumper JP30, if installed, enables setting the hard sector size over the ESDI interface. The drive must be in hard sector mode, (i.e. JP31 removed). +-----------+---------------+ | Jumper |# Bytes/Sector | +-----------+---------------+ | J16 | 1 | +-----------+---------------+ | J17 | 2 | +-----------+---------------+ | J18 | 4 | +-----------+---------------+ | J19 | 8 | +-----------+---------------+ | J20 | 16 | +-----------+---------------+ | J21 | 32 | +-----------+---------------+ | J22 | 64 | +-----------+---------------+ | J23 | 128 | +-----------+---------------+ | J24 | 256 | +-----------+---------------+ | J25 | 512 | +-----------+---------------+ | J26 | 1,024 | +-----------+---------------+ | J27 | 2,048 | +-----------+---------------+ | J28 | 4,096 | +-----------+---------------+ | J29 | 8,192 | +-----------+---------------+ Example: 36 Sectors Desired 1. 20,940 ------ = 581 Bytes/Sector 36 2: Install Jumpers J25 + J22, J18, +J16 # Bytes/Sector 512 + 64 + 4 + 1 = 581 JP32-35, JP38 Data Head Selection Jumpers ------------------------------------------ +--------+-----------+----------------------------------+ |Drive |Number of | Jumper Configuration | |Model |Data Heads |JP32 |JP33 |JP34 |JP35 |JP38 | +--------+-----------+------+------+------+------+------+ |XT-4170E| 7 |CLOSED|CLOSED|CLOSED|OPEN |OPEN | +--------+-----------+------+------+------+------+------+ |XT-4230E| 9 |CLOSED|CLOSED|CLOSED|OPEN |CLOSED| +--------+-----------+------+------+------+------+------+ |XT-4380E| 15 |CLOSED|CLOSED|CLOSED|CLOSED|OPEN | +--------+-----------+------+------+------+------+------+ Jumpers have been provided to allow the number of usable data heads to be selected. In order for the drive to respond correctly to the request configuration command - number of heads, these jumpers are set at the factory to correspond with the model of the drive. JP41, JP42, JP1 Test Jumpers ----------------------------- +-------+---------+--------------------------+ |Jumper | Factory | Notes on Function | | | Setting | | +-------+---------+--------------------------+ | JP1 | CLOSED | Write Data | +-------+---------+--------------------------+ | JP41 | N/A | Test Pins, Not Jumperable| +-------+---------+--------------------------+ | JP42 | CLOSED | Write Gate | +-------+---------+--------------------------+ These jumpers provide access to certain test signals. J6 Spindle Synchronization -------------------------- Jumper J6 is the spindle synchronization connector and is connected to the drives using this option. J3 DC Power and pin connector assignments ------------------------------------------- +------------+ pin 1 +12 VDC | 4 3 2 1 | pin 2 +12 Volts Return +------------+ pin 3 + 5 Volts Return pin 4 + 5 VDC ********************************************************************** I N S T A L L ********************************************************************** MAXTOR XT-4000E FAMILY QUICK REFERENCE GUIDE 1018329 REV. B Notes on Installation ===================== Installation direction ---------------------- horizontally vertically +-----------------+ +--+ +--+ | | | +-----+ +-----+ | | | | | | | | | +-+-----------------+-+ | | | | | | +---------------------+ | | | | | | | | | | | | | | | | | | +---------------------+ | +-----+ +-----+ | +-+-----------------+-+ +--+ +--+ | | | | +-----------------+ Mounting -------- The drive may be mounted in any orientation. In any final mounting configuration, ensure that the operation of the three shock mounts which, isolate the base casting from the frame is not restricted. Mounting Holes -------------- Eight mounting holes, four on the bottom and two on each side, are provided for mounting the drive into an enclosure. The size and location of these holes are identical to industry standard floppy drives. Caution: The casting is very close to the frame mounting holes in some locations. Mounting screws lengths must be chosen such that no more than 0.125 inch of the screw is available to enter the frame mounting hole. The torque applied to the mounting screws must be between 9 and 12 inch pounds. J1/P1 SCSI Connector -------------------- Connection to J1 is via a 34-pin PCB edge connector. The pins are numbered 1 through 34 with the even pins located on the component side of the PCB. Pin 2 is located on the end of the PCB connector closest to the DC power connector J3/P3. A key slot is provided be- tween pins 4 and 6. The recommended mating connector for P1 is AMP ribbon connector P/N 88373-3 or equivalent. J2/P2 Connector --------------- Connection of J2 is via a 20-pin PCB edge connector. The pins are numbered 1 through 20 with the even pins located on the component side of the PCB. The recommended mating connector for P2 is AMP ribbon connector P/N 88373-6. A key slot is provided between pins 4 and 6. J3/P3 Power Connector --------------------- The DC power connector, J3, is a four-pin AMP MATE-N-LOCK connector justify margin P/N 350543-1 mounted on the solder side of the PCB. The recommended mating connector is P/N 1-480424-0 using AMP pins part number 350078-4 (strip) or part number 61173-4 (loose piece). J4/P4 Ground ------------ The frame ground connector is a Faston-type connector, AMP part number 61761-2. The recommended mating connector is AMP part number 62187-1. If wire is used, the hole in J4 will accommodates a maximum wire size of 18 AWG. J6/P6 Auxiliary Connector ------------------------- The auxiliary connector is a Berg 68451-121 ten-pin connector. The mating connector is a 3M 3473-6010. +----------------------+---+ |Signal Name |Pin| +----------------------+---+ |MAPOUT | 1 | +----------------------+---+ |MAPIN | 2 | +----------------------+---+ |GND | 3 | +----------------------+---+ |MAPIN | 4 | +----------------------+---+ |GND | 5 | +----------------------+---+ |KEY (N.C.) | 6 | +----------------------+---+ |- REMOTE WRITE PROTECT| 7 | +----------------------+---+ | | 8 | +----------------------+---+ |- LED | 9 | +----------------------+---+ |+ LED |10 | +----------------------+---+ Removable Faceplate ------------------- The faceplate may be removed in installations where it is not required. Remove the two C-clips and unplug the LED cable from the PCB. ********************************************************************** F E A T U R E S ********************************************************************** MAXTOR XT-4000E FAMILY QUICK INSTALLATION GUIDE 1018329 REV. B Seek Time --------- | 4170E | 4230E | 4380E | ----------------------------------+--------+--------+--------+ Track-to-Track msec. typ. | 2.5 | 2.5 | 2.5 | msec. max. | 3 | 3 | 3 | ----------------------------------+--------+--------+--------+ Average msec. typ. | 14 | 16 | 16 | Average msec. max. | 16 | 17 | 18 | ----------------------------------+--------+--------+--------+ Full Stroke msec. typ. | 27 | 29 | 29 | msec. max. | 34 | 34 | 34 | ----------------------------------+--------+--------+--------+ Latency msec. avg. | 8.33 | 8.33| 8.33| ----------------------------------+--------+--------+--------+ Seek Time includes Settling Time. Reliability Specifications -------------------------- MTBF 150,000 Hours PM None Required MTTR 30 Minutes Component Design Life 5 Years