TANDBERG DATA
TDC 3620, TDC 3640, TDC 3660 (VER. 2)
| 
 Device Type  | 
 Tape Drive  | 
| 
 Interface  | 
 SCSI-2  | 
| 
 Format  | 
 QIC-24 (TDC3620), QIC-120 (TDC3640), QIC-150 (TDC3660 VER. 2)  | 
| 
 Sustained Transfer Rate  | 
 Unidentified  | 
| 
 Size  | 
 5.25 in. half height  | 
| 
 View  | 
 Top  | 
| 
 CONNECTIONS  | |
| 
 Function  | 
 Label  | 
| 
 Ground connector  | 
 CN1  | 
| 
 Note: CN1 not present on all models.  | |
| 
 USER CONFIGURABLE SETTINGS  | |||
| 
 Setting  | 
 Label  | 
 Position  | |
| » | 
 Factory configured - do not alter. (Serial communication out)  | 
 JP1/Pins 1 & 2  | 
 Unidentified  | 
| » | 
 Factory configured - do not alter. (Serial communication in)  | 
 JP1/Pins 3 & 4  | 
 Unidentified  | 
| 
 Parity check enabled  | 
 JP1/Pins 5 & 6  | 
 Closed  | |
| 
 Parity check disabled  | 
 JP1/Pins 5 & 6  | 
 Open  | |
| 
 DRIVE SELECT ID  | ||||
| 
 Drive ID  | 
 JP1/Pins 7 & 8  | 
 JP1/Pins 9 & 10  | 
 JP1/Pins 11 & 12  | |
| » | 
 0  | 
 Open  | 
 Open  | 
 Open  | 
| 
 1  | 
 Open  | 
 Open  | 
 Closed  | |
| 
 2  | 
 Open  | 
 Closed  | 
 Open  | |
| 
 3  | 
 Open  | 
 Closed  | 
 Closed  | |
| 
 4  | 
 Closed  | 
 Open  | 
 Open  | |
| 
 5  | 
 Closed  | 
 Open  | 
 Closed  | |
| 
 6  | 
 Closed  | 
 Closed  | 
 Open  | |
| 
 7  | 
 Closed  | 
 Closed  | 
 Closed  | |
| 
 Note: Pins 2 & 4 of JP1 must be open to enable SCSI ID select. With Pins 2 & 4 of JP1 closed, factory test functions are enabled via pins 7-12.  | ||||
| 
 MANUFACTURERS RECOMMENED MEDIA  | |||
| 
 Drive  | 
 Tape  | 
 Capacity Without Compression  | 
 Capacity With Compression  | 
| 
 TDC 3620  | 
 3M® DC300XL 137m  | 
 45MB  | 
 Unidentified  | 
| 
 TDC 3620  | 
 3M® DC300XLP 137m  | 
 45MB  | 
 Unidentified  | 
| 
 TDC 3620  | 
 DEI 169m  | 
 55MB  | 
 Unidentified  | 
| 
 TDC 3620  | 
 DEI Ser. II Gold Plus 169m  | 
 55MB  | 
 Unidentified  | 
| 
 TDC 3620  | 
 3M® DC600A 183m  | 
 60MB  | 
 Unidentified  | 
| 
 TDC 3620  | 
 3M® DC600XTD 183m  | 
 60MB  | 
 Unidentified  | 
| 
 TDC 3640  | 
 3M® DC600A 183m  | 
 125MB  | 
 Unidentified  | 
| 
 TDC 3640  | 
 3M® DC600XTD 183m  | 
 125MB  | 
 Unidentified  | 
| 
 TDC 3660 (VER. 2)  | 
 3M® DC600A 183m  | 
 125MB  | 
 Unidentified  | 
| 
 TDC 3660 (VER. 2)  | 
 3M® DC600XTD 183m  | 
 125MB  | 
 Unidentified  | 
| 
 TERMINATING RESISTOR CONFIGURATION  | |||
| 
 Function  | 
 RP1  | 
 RP2  | 
 RP3  | 
| 
 Termination enabled  | 
 Terminator installed  | 
 Terminator installed  | 
 Terminator installed  | 
| 
 Termination disabled  | 
 Terminator not installed  | 
 Terminator not installed  | 
 Terminator not installed  | 
| 
 DIAGNOSTIC LED(S)  | |||||||
| 
 LED1 (Red) Blink-Code*  | 
 Condition  | 
 Fatal Error  | |||||
| 
 Short  | 
 Short  | 
 Short  | 
 Short  | 
 Short  | 
 Short  | 
 No error  | |
| 
 Short  | 
 Short  | 
 Short  | 
 Short  | 
 Short  | 
 Long  | 
 Append error  | |
| 
 Short  | 
 Short  | 
 Short  | 
 Short  | 
 Long  | 
 Short  | 
 Bad command block  | |
| 
 Short  | 
 Short  | 
 Short  | 
 Short  | 
 Long  | 
 Long  | 
 Bad parameter block  | |
| 
 Short  | 
 Short  | 
 Short  | 
 Long  | 
 Short  | 
 Short  | 
 Bus parity error  | |
| 
 Short  | 
 Short  | 
 Short  | 
 Long  | 
 Short  | 
 Long  | 
 Busy  | |
| 
 Short  | 
 Short  | 
 Short  | 
 Long  | 
 Long  | 
 Short  | 
 Capst. servo error  | 
 B  | 
| 
 Short  | 
 Short  | 
 Short  | 
 Long  | 
 Long  | 
 Long  | 
 Cartridge removed  | |
| 
 Short  | 
 Short  | 
 Long  | 
 Short  | 
 Short  | 
 Short  | 
 Compare error  | |
| 
 Short  | 
 Short  | 
 Long  | 
 Short  | 
 Short  | 
 Long  | 
 Copy data error  | |
| 
 Short  | 
 Short  | 
 Long  | 
 Short  | 
 Long  | 
 Short  | 
 Copy managem. error  | |
| 
 Short  | 
 Short  | 
 Long  | 
 Short  | 
 Long  | 
 Long  | 
 File mark error  | |
| 
 Short  | 
 Short  | 
 Long  | 
 Long  | 
 Short  | 
 Short  | 
 Head servo error  | 
 B  | 
| 
 Short  | 
 Short  | 
 Long  | 
 Long  | 
 Short  | 
 Long  | 
 Illegal command  | |
| 
 Short  | 
 Short  | 
 Long  | 
 Long  | 
 Long  | 
 Short  | 
 Illeagal copy  | |
| 
 Short  | 
 Short  | 
 Long  | 
 Long  | 
 Long  | 
 Long  | 
 Illegal length  | |
| 
 Short  | 
 Long  | 
 Short  | 
 Short  | 
 Short  | 
 Short  | 
 Inappropriate request  | |
| 
 Short  | 
 Long  | 
 Short  | 
 Short  | 
 Short  | 
 Long  | 
 Latch error  | 
 A  | 
| 
 Short  | 
 Long  | 
 Short  | 
 Short  | 
 Long  | 
 Short  | 
 No cartridge  | |
| 
 Short  | 
 Long  | 
 Short  | 
 Short  | 
 Long  | 
 Long  | 
 Not loaded  | |
| 
 Short  | 
 Long  | 
 Short  | 
 Long  | 
 Short  | 
 Short  | 
 Power-on request  | |
| 
 Short  | 
 Long  | 
 Short  | 
 Long  | 
 Short  | 
 Long  | 
 QIC. No data detected  | |
| 
 Short  | 
 Long  | 
 Short  | 
 Long  | 
 Long  | 
 Short  | 
 Read after write error  | |
| 
 Short  | 
 Long  | 
 Short  | 
 Long  | 
 Long  | 
 Long  | 
 Read EOM logical  | |
| 
 Short  | 
 Long  | 
 Long  | 
 Short  | 
 Short  | 
 Short  | 
 Read EOM physical  | |
| 
 Short  | 
 Long  | 
 Long  | 
 Short  | 
 Short  | 
 Long  | 
 Reserv. Conflict  | |
| 
 Short  | 
 Long  | 
 Long  | 
 Short  | 
 Long  | 
 Short  | 
 Sensor error  | 
 B  | 
| 
 Short  | 
 Long  | 
 Long  | 
 Short  | 
 Long  | 
 Long  | 
 Tape runnout  | 
 B  | 
| 
 Short  | 
 Long  | 
 Long  | 
 Long  | 
 Short  | 
 Short  | 
 Unit attention  | |
| 
 Short  | 
 Long  | 
 Long  | 
 Long  | 
 Short  | 
 Long  | 
 Write EOM warning  | |
| 
 Short  | 
 Long  | 
 Long  | 
 Long  | 
 Long  | 
 Short  | 
 Write EOM  | |
| 
 Short  | 
 Long  | 
 Long  | 
 Long  | 
 Long  | 
 Long  | 
 Cartridge write prot.  | |
| 
 Long  | 
 Short  | 
 Short  | 
 Short  | 
 Short  | 
 Short  | 
 16 rewrite errors  | |
| 
 Long  | 
 Short  | 
 Short  | 
 Short  | 
 Short  | 
 Long  | 
 24 rereads. Blk. fnd.  | |
| 
 Long  | 
 Short  | 
 Short  | 
 Short  | 
 Long  | 
 Short  | 
 24 rereads. Not fnd.  | |
| 
 Long  | 
 Short  | 
 Short  | 
 Short  | 
 Long  | 
 Long  | 
 Illegal copy function  | |
| 
 Long  | 
 Short  | 
 Short  | 
 Long  | 
 Short  | 
 Short  | 
 Illegal header  | |
| 
 Long  | 
 Short  | 
 Short  | 
 Long  | 
 Short  | 
 Long  | 
 No header  | |
| 
 Long  | 
 Short  | 
 Short  | 
 Long  | 
 Long  | 
 Short  | 
 Too large address  | |
| 
 Long  | 
 Short  | 
 Short  | 
 Long  | 
 Long  | 
 Long  | 
 Bad ID or LUN  | |
| 
 Long  | 
 Short  | 
 Long  | 
 Short  | 
 Short  | 
 Short  | 
 Partial Description  | |
| 
 Long  | 
 Short  | 
 Long  | 
 Short  | 
 Short  | 
 Long  | 
 Bad target status  | |
| 
 Long  | 
 Short  | 
 Long  | 
 Short  | 
 Long  | 
 Short  | 
 Check condition  | |
| 
 Long  | 
 Short  | 
 Long  | 
 Short  | 
 Long  | 
 Long  | 
 Data transfer error  | |
| 
 Long  | 
 Short  | 
 Long  | 
 Long  | 
 Short  | 
 Short  | 
 Selection failure  | |
| 
 DIAGNOSTIC LED(S) CONTINUED  | |||||||
| 
 LED1 (Red) Blink-Code*  | 
 Condition  | 
 Fatal Error  | |||||
| 
 Long  | 
 Short  | 
 Long  | 
 Long  | 
 Short  | 
 Long  | 
 Sequence error  | |
| 
 Long  | 
 Short  | 
 Long  | 
 Long  | 
 Long  | 
 Short  | 
 Illegal block size  | |
| 
 Long  | 
 Long  | 
 Short  | 
 Short  | 
 Short  | 
 Long  | 
 Buffer size error  | 
 A  | 
| 
 Long  | 
 Long  | 
 Short  | 
 Short  | 
 Long  | 
 Short  | 
 Rereads outside limits  | |
| 
 Long  | 
 Long  | 
 Short  | 
 Short  | 
 Long  | 
 Long  | 
 Rewrites outside limits  | |
| 
 Long  | 
 Long  | 
 Short  | 
 Long  | 
 Short  | 
 Short  | 
 Buffer error. Low nibble  | 
 A  | 
| 
 Long  | 
 Long  | 
 Short  | 
 Long  | 
 Short  | 
 Long  | 
 Buffer error. High nibble  | 
 A  | 
| 
 Long  | 
 Long  | 
 Short  | 
 Long  | 
 Long  | 
 Short  | 
 Unspec. fatal error  | |
| 
 Long  | 
 Long  | 
 Short  | 
 Long  | 
 Long  | 
 Long  | 
 Timeout error  | 
 B  | 
| 
 Long  | 
 Long  | 
 Long  | 
 Short  | 
 Short  | 
 Short  | 
 Buffer RAM error  | 
 A  | 
| 
 Long  | 
 Long  | 
 Long  | 
 Short  | 
 Short  | 
 Long  | 
 Drive contr. Error  | 
 A  | 
| 
 Long  | 
 Long  | 
 Long  | 
 Short  | 
 Long  | 
 Short  | 
 EEPROM verification  | 
 A  | 
| 
 Long  | 
 Long  | 
 Long  | 
 Short  | 
 Long  | 
 Long  | 
 EEPROM error  | 
 A  | 
| 
 Long  | 
 Long  | 
 Long  | 
 Long  | 
 Short  | 
 Short  | 
 External RAM error  | 
 A  | 
| 
 Long  | 
 Long  | 
 Long  | 
 Long  | 
 Short  | 
 Long  | 
 SCSI contr. Error  | 
 A  | 
| 
 Long  | 
 Long  | 
 Long  | 
 Long  | 
 Long  | 
 Short  | 
 Spurious interrupt  | 
 B  | 
| 
 Long  | 
 Long  | 
 Long  | 
 Long  | 
 Long  | 
 Long  | 
 Stack overflow  | 
 B  | 
| 
 Note: Type ‘A’ Code: Error cannot be reset. Drive will continue to report error with a blinking code once initial error has occurred. Service is required. Type ‘B’ Code: Errors are failures in the Drive or the cartridge. Error can be cleared by RESET and information saved in EEPROM.  | |||||||
.