TECMAR
WANGTEK 5525ES (33959-XXX)
| 
 Device Type  | 
 Internal Tape Drive  | 
| 
 Interface  | 
 SCSI-1, SCSI-2  | 
| 
 Format  | 
 QIC-120, QIC-150, or QIC525 (write) QIC-24, QIC-120, QIC-150, or QIC-525 (read)  | 
| 
 Sustained Transfer Rate  | 
 200 KBPS  | 
| 
 Size  | 
 5.25 in. half height  | 
| 
 View  | 
 Bottom  | 
| 
 CONNECTIONS  | |
| 
 Function  | 
 Label  | 
| 
 Chassis ground connector  | 
 W1  | 
| 
 USER CONFIGURABLE SETTINGS  | |||
| 
 Setting  | 
 Label  | 
 Position  | |
| » | 
 Factory configured - do not alter (Built in test mode(s))  | 
 E2  | 
 Open  | 
| » | 
 Factory configured - do not alter  | 
 E3  | 
 Unidentified  | 
| » | 
 Factory configured - do not alter (Built in test mode(s))  | 
 E4  | 
 Open  | 
| » | 
 Factory configured - do not alter (48 MHz main oscillator enabled)  | 
 E5  | 
 Closed  | 
| » | 
 1024 byte block mode enabled  | 
 JP2  | 
 Open  | 
| 
 512 byte block mode enabled  | 
 JP2  | 
 Closed  | |
| » | 
 Factory configured - do not alter (Built in test mode(s))  | 
 JP3  | 
 Open  | 
| » | 
 Factory configured - do not alter (Built in test mode(s))  | 
 JP6  | 
 Open  | 
| » | 
 Factory configured - do not alter  | 
 JP7  | 
 Unidentified  | 
| » | 
 Factory configured - do not alter  | 
 JP8  | 
 Unidentified  | 
| » | 
 Factory configured - do not alter  | 
 JP9  | 
 All pins open  | 
| » | 
 Factory configured - do not alter (Built in test mode(s))  | 
 JP12  | 
 Open  | 
| » | 
 Factory configured - do not alter (Diagnostic test connector)  | 
 JP32  | 
 Open  | 
| 
 DRIVE SELECT ID  | ||||
| 
 Drive ID  | 
 JP1/A  | 
 JP1/B  | 
 JP1/C  | |
| » | 
 0  | 
 Open  | 
 Open  | 
 Open  | 
| 
 1  | 
 Closed  | 
 Open  | 
 Open  | |
| 
 2  | 
 Open  | 
 Closed  | 
 Open  | |
| 
 3  | 
 Closed  | 
 Closed  | 
 Open  | |
| 
 4  | 
 Open  | 
 Open  | 
 Closed  | |
| 
 5  | 
 Closed  | 
 Open  | 
 Closed  | |
| 
 6  | 
 Open  | 
 Closed  | 
 Closed  | |
| 
 7  | 
 Closed  | 
 Closed  | 
 Closed  | |
| 
 Note: Jumper JP1/D is factory configured and should not be altered. The default position for JP1/D is Open.  | ||||
| 
 TERMINATION POWER SELECTION  | ||
| 
 Setting  | 
 E1  | |
| » | 
 TERMPWR supplied by drive  | 
 Closed  | 
| 
 TERMPWR supplied by SCSI interface to drive  | 
 Open  | |
| 
 Note: The fuse at F1 must be installed when TERMPWR is supplied by the drive.  | ||
| 
 MISCELLANEOUS TECHNICAL NOTES  | 
| 
 Termination is enabled or disabled via the three removable terminating resistors (see diagram).  |